D. Increased alveolar dead space because ventilation persists without perfusion
Why this is correct
An acute pulmonary embolus reduces perfusion to still-ventilated alveoli. Their ventilation–perfusion ratio becomes very high (approaches infinity when perfusion is absent), creating alveolar dead space. Other lung regions may develop low V/Q ratios contributing to hypoxemia; therefore the global disturbance can be complex.
Why each option is correct or incorrect
Low ventilation with preserved perfusion is a low V/Q state, not the direct effect of an arterial embolus.
An anatomic right-to-left shunt describes perfused but nonventilated regions; PE initially creates ventilated but unperfused units.
An embolus obstructs rather than augments blood flow in the affected vessel.
Correct: perfusion falls while ventilation continues, increasing dead-space ventilation.
High-yield notes
- V/Q → infinity = dead space (ventilation without perfusion).
- V/Q → 0 = shunt-like physiology (perfusion without ventilation).
- Pulmonary embolism can increase the alveolar–arterial oxygen gradient.
Pulmonary embolism classically causes increased alveolar dead space.
Hypoxemia in pulmonary embolism does not mean the occluded units are shunting; they are initially dead-space units.